400G QSFP-DD LR 10km Modulu Ottiku
Mudell: HTQD-400GLR4
Karatteristiċi tal-Modulu Ottiku 400G LR4
Jappoġġja 400GBASE-LR4
Lane bit rate 106.25 Gb/s b'PAM4
Trażmissjoni sa 10km fuq SMF
Lejżer CWDM4 u riċevitur PIN
8x53.125Gb/s b'interface elettrika PAM4 (400GAUI-8)
Interface I2C b'monitoraġġ Dijanjostiku Diġitali integrat
Pakkett QSFP-DD MSA b'konnettur duplex LC
Provvista ta 'enerġija waħda +3.3V
Konsum massimu ta 'enerġija 12 W
Temperatura tal-kaxxa operattiva: 0 sa +70 grad
Konformi mal-istandard QSFP-DD CMIS rev4.0
Konformi mal-400G-LR4-10 Speċifikazzjoni Teknika
Konformi mal-istandard QSFP-DD MSA HW
Jikkonforma mad-Direttiva tal-UE 2015/863/UE
Applikazzjoni
400GBASE-LR4;
Netwerk 400G Ethernet/DCI/Metro
Informazzjoni dwar l-Ordni
Tabella1- informazzjoni dwar l-ordni
|
Nru tal-Parti. |
Rata tad-Data |
Laser |
Tip ta' Fibra |
Distanza |
Ottiċi Interface |
Temp |
DDMI |
|
HTQD-400GLR4 |
425Gbps |
CWDM4 |
SMF |
10km |
LC |
0~70C |
Y |
Klassifikazzjonijiet Massimu Assoluti
Tabella2-Klassifikazzjonijiet Massimi Assoluti
|
Parametru |
Simbolu |
Min. |
Tipiku |
Massimu |
Unità |
Noti |
|
Temperatura tal-Ħażna |
TS |
-40 |
- |
+85 |
grad |
|
|
Vultaġġ tal-Provvista |
VCC |
-0.5 |
- |
+4.0 |
V |
|
|
Umdità Relattiva operattiva |
RH |
- |
- |
+85 |
% |
Kundizzjonijiet Operattivi Rakkomandati
Tabella3-Kundizzjonijiet Operattivi Rakkomandati
|
Parametru |
Simbolu |
Min. |
Tipiku |
Massimu |
Unità |
Noti |
|
Temperatura tal-Każ Operattiv |
TC |
0 |
- |
+70 |
grad |
|
|
Vultaġġ tal-Provvista tal-Enerġija |
VCC |
3.13 |
3.3 |
3.47 |
V |
|
|
Kurrent tal-Provvista tal-Enerġija |
ICC |
- |
- |
3.46 |
A |
|
|
Dissipazzjoni tal-Qawwa Massima |
PD |
- |
- |
12 |
W |
|
|
Rata Bit Aggregata |
KURAĠĠUŻI |
- |
425 |
- |
Gb/s |
Bil PAM4 |
|
Lane Bit Rata |
BLANE |
- |
106.25 |
- |
Gb/s |
Bil PAM4 |
|
Distanza tat-Trażmissjoni |
TD |
- |
- |
10 |
Km |
Fuq SMF |
Karatteristiċi Ottiċi
Tabella4-Karatteristiċi Ottiċi
|
Trasmettitur |
||||||
|
Parametru |
Simbolu |
Min. |
Tipiku |
Massimu |
Unità |
Noti |
|
Korsija taċ-Ċentru tal-Wavelength 0 |
λ0 |
1264.5 |
1271 |
1277.5 |
nm |
|
|
Ċentru Wavelength Lane 1 |
λ1 |
1284.5 |
1291 |
1297.5 |
nm |
|
|
Ċentru Wavelength Lane 2 |
λ2 |
1304.5 |
1311 |
1317.5 |
nm |
|
|
Ċentru Wavelength Lane 3 |
λ3 |
1324.5 |
1331 |
1337.5 |
nm |
|
|
Qawwa Totali tat-Tnedija |
PALL |
- |
- |
10 |
Dbm |
1 |
|
Qawwa Medja tat-Tnedija għal kull Lane |
PTX{0}}LANE |
-2.7 |
- |
5.1 |
Dbm |
1 |
|
OMAoutter għal kull Lane |
OMAbarra |
0.3 |
- |
4.4 |
dBm |
2 |
|
Qawwa tat-tnedija f'OMAouter nieqes TDECQ kull korsija |
OMAbarra- TDECQ |
-1.2 |
ER Akbar minn jew ugwali għal 4.5dB |
|||
|
-1.1 |
ER<4.5dB |
|||||
|
Għeluq tal-għajnejn tat-trasmettitur u t-tixrid għal PAM4 (TDECQ), għal kull korsija |
TDECQ |
- |
- |
3.9 |
dB |
|
|
Differenza fil-qawwa tal-varar bejn kwalunkwe żewġ korsiji (OMAouter) |
PTX_DELTA_LANE |
- |
- |
4 |
Db |
|
|
Qawwa medja tal-Ħruġ (Laser Itfi) |
MITFI |
- |
- |
-16 |
Dbm |
|
|
Proporzjon ta 'Soppressjoni tal-Modalità tal-Ġenb |
SMSR |
30 |
- |
- |
Db |
|
|
Proporzjon ta' Estinzjoni |
ER |
3.5 |
- |
- |
Db |
|
It-tags Popolari: 400g qsfp-dd lr 10km ottika modulu, Ċina, manifatturi, fornituri, fabbrika, personalizzati, jixtru, prezz, bl-ingrossa, marka kompatibbli